GlobeCore has designed TOR-7, a multipurpose tester that can be used by both electrical lab and transformer maintenance company personnel. TOR-7 measures four key parameters of transformer oil: volumetric gas content, moisture content, solids contamination level, and content of hydrogen as a key gas in chromatographic analysis to determine possible defects occurring in a transformer.

General view of TOR-7 tester

The principle of the tester’s operation is based on recording a change in gas pressure inside a cylinder under vacuum when it is filled with a portion of oil. Knowing the volumes of the cylinder and of the oil filled, the pressure inside the cylinder before and after filling makes it possible to determine the volumetric gas content.

The moisture content and temperature of oil, the hydrogen content, and the amount of solids in oil are calculated and visually displayed through the use of sensors and a controller board.

If necessary, the measurement results can be printed out with the use of an integrated mini-printer.

Table 1 – Specifications of TOR-7 tester

No.ParameterValue  
Moisture measurement specifications
1Operating range, aw (active water (aw))0…1  
2Precision at 20 °C±0.02 aw (0…0.9 aw) ±0.03 aw (0.9…1 aw)  
3Temperature measurementYes  
4Operating medium temperature, °С0…55  
Hydrogen measurement specifications
6Measurement range, ppm25–5,000  
7Precision20% of indication, or 25 ppm  
8Repeatability10% of indication, or 15 ppm  
9Response time<60 min (90% step change)  
10Сross-sensitivityLess than 2% cross-sensitivity to other gases (CO, CO2, hydrocarbons)  
11Operating medium temperature, °С0…55  
Solids contamination measurement specifications
6Measurement range, ppm25–5000  
7Precision20% of indication, or 25 ppm  
8Repeatability10% of indication, or 15 ppm  
9Response time<60 min (90% step change)  
10Cross-sensitivityLess than 2% cross-sensitivity to other gases (CO, CO2, hydrocarbons)  
11Operating medium temperature, °С0…55  
Purity or contamination levels
12Permissible viscosity range, mm²/s1 to 1,000  
13Measured variablesISO 99 (ISO 4406:1999)SAE (SAE AS 4059), orISO 87 (ISO 4406:1987)NAS (NAS 1638)  
14Measurement rangeMeasurement from ISO 9/8/7 (MIN) to ISO 25/24/23 (MAX)Calibrated within the ISO range from 13/11/10 to 23/21/18  
15Precision+/- 1/2 of ISO class in the calibrated range  
16Operating medium temperature, °С0 … +85

Summary

Thus, TOR-7 provides the most appropriate set of data for rapid diagnostic evaluation of transformer oil: volumetric gas content, moisture content, solids content, and hydrogen content. The obtained information allows saving time and money on lab analyses, as well as making quick decisions as part of transformer maintenance program (further use, more complete analysis, or purification of oil). Prompt decision-making contributes to preventing the occurrence of defects in due course through timely oil treatment and enhancing the reliability of transformers operation.